Summary Report for sample "Ricles-ATLSS0413-SPEC3-W"
Warning: Trying to access array offset on null in /var/www/html/steel/report.php on line 217
General Information
- Specimen identification according to official publication: Ricles-ATLSS0413-SPEC3-W
Test Configuration and Connection Type
- Test configuration:
- Beam-to-column connection type: RBS
- Pre-Northridge connection type: No
- Load control type: displacement
Warning: Undefined array key "BD_Fu_M" in /var/www/html/steel/report.php on line 284
Warning: Undefined array key "BD_Fu_M" in /var/www/html/steel/report.php on line 285
Subassembly Geometry
- Beam size: W36x150
- Column size: W27x194
- Beam length to centerline of column (BLE) : 177.0 in
- Beam effective length from load or support point to idealized plastic hinge location (section of maximum curvature): 140.44 in
- Column length to centerline of the beam (CLC): 78.00 in
- Column effective length from load or support point to idealized plastic hinge location (section of maximum curvature): 60.06 in
Material Properties
- Material designation: A992Gr.50
- Nominal yield stress: 50 ksi
- Yield stress based on mill certificate (Fym): 57.1 ksi
- Measured yield stress of flange (Fyf): 53.0 ksi
- Measured yield stress of web (Fyw): 57.4 ksi
- Measured ultimate stress of flange (Fuf): 73.7 ksi
- Measured ultimate stress based on mill certificate (Fum): ksi
- Measured ultimate stress of web (Fuw): ksi
Lateral Bracing
- Type of lateral support: lateral braces
- Distance at which lateral support restrains the top flange of the beam: 164.5 in
- Distance at which additional lateral support restrains the top flange of the beam 54_ 120 in
- Distance at which lateral support restrains the bottom flange of the beam: 164.5 in
- Distance at which additional lateral support restrains the bottom flange of the beam: 0
Panel Zone Geometry
- Thickness of welder stiffeners at the panel zone: 1.000 in
- Are doubler plates welded in the panel zone? : Yes
Fatal error: Uncaught Error: Undefined constant "Dbl_pl_PZ" in /var/www/html/steel/report.php:301 Stack trace: #0 {main} thrown in /var/www/html/steel/report.php on line 301